Network Appliance C1200 NetCache Service Manual page 49

Table of Contents

Advertisement

Operational
messages
Error message
Disk n is broken
Fans stopped; replace
them
Power supply degraded
Chapter 5: Error Messages and Troubleshooting
Sensor type
Power voltage sensors
Power supply sensors
The following table describes the operational error messages that might appear
on the C2100 appliance LCD or on the C1200 console, if the appliance
encounters errors during operation.
Explanation
n—The RAID group disk number.
The solution depends on whether you
have a hot spare in the system—
C2100 only.
One of the fan subassemblies of the
appliance failed.
One of the power supply units is
turned off, was removed from the
appliance, or failed.
C2100 sensors
Baseboard 1.25V
Baseboard 2.5V
Baseboard 3.3V
Baseboard 3.3VSB
Baseboard 5.0V
Baseboard 12V
Baseboard -12V
Baseboard VBAT
Baseboard VRM
Power Supply 1
Power Supply 2
Corrective action
See the System Administration Guide
for information about how to locate a
disk based on the RAID group disk
number and how to replace a faulty
disk.
Replace the failed fan subassembly as
soon as possible.
Verify that both power supplies are
installed and turned on. If you still get
this error, replace the power supplies
one at a time to determine the failed
power supply.
C1200 sensors
Baseboard 1.25V
Baseboard 2.5V
Baseboard 3.3V
Baseboard 3.3VSB
Baseboard 5.0V
Baseboard 12V
Baseboard -12V
Baseboard VBAT
Baseboard VRM
Power Supply 1
N/A