Boot error message
Cannot read labels
Disk label processing
failed
Halted: firmware too
old
No disks
Drive %s.%d not
supported
Halted: Illegal
configuration
Chapter 5: Error Messages and Troubleshooting
Explanation
When the appliance tries to initialize a
new file system, it has a problem
reading the disk labels it wrote to the
disks.
This problem can be because the
system failed to read the disk size, or
the written disk labels were invalid
The appliance detects that the disk is
not in the correct drive bay.
The disk firmware is an old version.
The system cannot detect any SCSI
disks.
%s—The disk number;
%d—The disk ID number. The system
detects an unsupported disk drive.
Incorrect cluster configuration.
Corrective action
Contact Network Appliance Customer
Support.
Make sure that the disk is in the
correct bay.
Update the disk firmware by entering
the following command:
disk_fw_update
Verify that all disks are properly seated
in the drive bays.
1. Remove the drive immediately or
the system drops down to the
PROM monitor within 30
seconds.
2. Check the System Configuration
Guide at
http://now.netapp.com
verify support for your disk drive.
1. Check the console for details.
2. Verify that all cables are correctly
connected.
to
35