Maintenance
item No.
Setting DP reading position modification operation
U087
Description
Sets the black line inspection at the time of reading the original from the DP.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select CCD at the screen for selecting an item.
2. Change the value using the cursor up/down keys.
Setting
Black line inspection
3. Press the start key. The value is set.
Setting
1. Select BLACK LINE at the screen for selecting an item.
2. Select CLEAR.
3. Press the start key. The setting is cleared.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
1-4-24
Description
Setting range
0 to 255
Service Manual
Default setting
200