Code
C6050
Fuser thermistor abnormal tempera-
ture detection
• During copying, the temperature at the
heat roller lower than 120
detected continuously for 5 s.
C6400
Zero-cross signal error
• The main PWB does not detect the
zero-crossing signal (Z CROSS SIG)
for 5 s.
C7200
Broken internal thermistor wire
• The thermistor output value is 4.5 V or
more.
C7210
Short-circuited internal thermistor
• The thermistor input value is 0.5 V or
less.
C7300
Toner hopper problem
• Toner level is not detected when toner
empty is detected.
C7800
Broken external thermistor wire
• The thermistor output value is 4.5 V or
more.
Y104350-7
Contents
°
°
C/248
F is
Causes
Check procedures/corrective measures
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor M and S. If any problem is found,
thermistor M and
repair it.
S.
Operation on fuser
Check for continuity. If none, replace the
thermostat.
fuser thermostat.
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor L, M and S. If any problem is found,
heater L, M or S.
repair it.
Broken fuser
Check for continuity. If none, replace the
heater L, M and S
fuser heater L, M and S (see page 1-6-76).
wire.
Poor contact in the
Check the connection of connectors YC11
connector termi-
on the main PWB and YC6 on the DC power
nals.
source PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective DC
Check if the zero-crossing signal is output
power source
from YC6-3 on the DC power source PWB.
PWB.
If not, replace the DC power source PCB.
Defective main
Replace the main PWB if C6400 is detected
PWB.
while YC6-3 on the DC power source PWB
outputs the zero-crossing signal.
Poor contact in the
Check the connection of connector YC23 on
connector termi-
the engine PWB and the continuity across
nals.
the connector terminals. Repair or replace if
necessary.
Defective develop-
Replace the developing humidity sensor.
ing humidity sen-
sor.
Poor contact in the
Check the connection of connector YC23 on
connector termi-
the engine PWB and the continuity across
nals.
the connector terminals. Repair or replace if
necessary.
Defective develop-
Replace the developing humidity sensor.
ing humidity sen-
sor.
Defective toner
Replace the toner level detection sensor.
level detection sen-
sor.
Poor contact in the
Reinsert the connector. Also check for conti-
toner level detec-
nuity within the connector cable. If none,
tion sensor con-
remedy or replace the cable.
nector terminals.
Poor contact in the
Check the connection of connector YC13 on
connector termi-
the engine PWB and the continuity across
nals.
the connector terminals. Repair or replace if
necessary.
Defective humidity
Replace the humidity sensor.
sensor.