14. Remove the scanner wire stoppers.
15. Remove two screws from each of the frame
securing tools and then the tools.
16. Focusing on the locating ball of the wire
drum, move aside the wires to inside.
17. Move the mirror 2 frame from side to side to
correctly locate the wires in position.
18. Refit the mirror 1 frame.
19. Move the mirror 1 and 2 frames to the
machine left, and insert the two frame secur-
ing tools into the positioning holes at the
front and rear of the scanner unit to secure
the frames in position.
20. Secure the two screws from each of the
frame securing tools and then the tools.
21. Hold the wires and fix each front and rear
wire holder plate to mirror 1 frame with the
screw.
22. Remove the frame securing tools.
23. Refit the slit glass.
24. Refit the upper operation unit cover, opera-
tion unit right and left covers and staple tray.
25. Refit the upper rear cover and DP.
26. Refit the upper left cover and exposure lamp
(see page 1-6-34).