13. Remove the stop ring and then remove the
DP separation roller.
14. Clean or replace the DP separation roller
and attach the roller.
* When replacing the DP separation roller, be
careful that the projection of torque limiter is
firmly into the groove of the DP separation
roller.
15. Insert the separation guide to the DP.
16. Refit the original feed pulley unit.
17. Refit the upper original feed cover.
1-6-86
Torque limiter
Service Manual
DP separation roller
Stop ring
Figure 1-6-170
Y104350-7