Olivetti d-Copia 600 Service Manual page 330

Color printer
Hide thumbs Also See for d-Copia 600:
Table of Contents

Advertisement

(4) Detaching and refitting the image formation fan filter
Follow the procedure below to replace the image formation filter.
Procedure
1. Remove the image formation fan cover
while pushing the lever.
2. Remove the image formation fan filter from
the image formation fan cover.
3. Replace the image formation fan filter and
attach the filter to the image formation fan
cover.
4. Refit the image formation fan cover.
1-6-98
Lever
Image formation
fan filter
Service Manual
Image formation
fan cover
Figure 1-6-190
Image formation
fan cover
Figure 1-6-191
Y104350-7