INSTALLATION
LP TANK INSTALLATION
KWDH/KWBH ONLY
NOTE: Max tank size 20lb.
1) Remove end panel (opposite end of gas knob panel).
2) Slide out LP gas tank by pulling from handle on slide out tray.
3) Undo butterfl y bolt to allow LP tank to be seated on the holder.
4) Place LP tank onto slide out try and screw in butterfl y bolt to secure
tank.
Butterfl y bolt
5) Push tank in from the bottom.
DO NOT PUSH IN FROM THE TOP OF THE TANK.
6) Connect the LP regulator quick connect to the tank
7) Check all gas connections (both valve train & propane tank) under nor-
mal operating pressure, for leaks, with soapy water.
NOTE: If soap bubbles, this would indicate a gas leak.
20
1) Remove end panel (opposite end of switch panel).
2) Ensure tank is fully closed. Disconnect gas line.
3) Slide out LP gas tank by pulling from handle on slide out tray.
NOTE: DO NOT SLIDE OUT TANK BY GRASPING FROM TOP OF TANK.
4) Undo butterfl y bolt to release tank.
5) Refi ll tank and reinstall by reversing steps.
Gas connection
@ tank

LP TANK REMOVAL

Slide out handle
Butterfl y bolt
Firegear Outdoors® Key West™ Series