12. Install regulator bracket onto unit base with 2 screws. Connect fl ex
line to regulator—position regulator onto bracket.
Regulator
Regulator
Bracket
Inlet pressure tap
13. Secure regulator in position with top bracket - secure with 2 screws.
NOTE: Top bracket to sit over top of lower bracket.
Attach supplied "MAX. 0.5 PSI" sticker to top bracket.
Top
Bracket
14. Remove connector from end of fl ex line.
Diagram 15
16
Diagram 13
Flexline
Diagram 14
Remove
connector
15. Connect fl ex line to valve fi tting.
Connect fl ex line
to valve
16. Attach the label "this unit has been converted to NG" near on top of
the serial # decal.
17. Replace red "LPG" label with yellow "NG" label.
18. Bring gas to appliance. The connector removed in previous steps
can be used on the inlet side of the regulator.
19. Check all gas connections (at valve, regulator, and NG outlet) under
normal operating pressure, for leaks, with soapy water.
NOTE: If soap bubbles, this would indicate a gas leak.
20. Check inlet and outlet pressures.
21. Reinstall panels.