INSTALLATION
KEY WEST SERIES-NG2 SYSTEM
DATA
Max. Supply Pressure
14" WC (3.49 kpa)
Min. Supply Pressure
5" WC (1.25 kpa)
Manifold Pressure
3.5" WC (0.87 kpa)
Manifold Pressure -Low
0.5" WC (0.12 kpa)
Orifi ce Size
#23 DMS
Minimum Input
18,000 Btu/h
(5.27 kW)
Maximum Input
49,000 Btu/h
(14.36 kW)
KEY WEST SERIES-LP2 SYSTEM
DATA
Max. Supply Pressure
14" WC (3.49 kpa)
Min. Supply Pressure
12" WC (2.99 kpa)
Manifold Pressure
11" WC (2.73 kpa)
Manifold Pressure-Low
1" WC (0.25 kpa)
Orifi ce Size
#45 DMS
Minimum Input
15,000 Btu/h
(4.39 kW)
Maximum Input
48,000 Btu/h
(14.06 kW)

HIGH ELEVATION

This unit is approved for altitude 0 to 4500 ft. (CAN/
CGA 2.17-M91).
GAS LINE
INSTALLATION
Since some municipalities have additional local
codes it is always best to consult with your local
authorities and the CAN/CGA B149 installation
code.
For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.
When using copper or fl ex connectors use only
approved fi ttings. Always provide a union so that
gas lines can be easily disconnected for servicing.
Flare nuts for copper lines and fl ex connectors are
usually considered to meet this requirement.
NOTE: A shutoff / dante valve should be sup-
plied in or near the unit (or as per local codes)
for ease of servicing this appliance.
IMPORTANT: Always check for gas leaks with
a soap and water solution or gas leak detector.
Do not use open fl ame for leak testing.
12
COPRECI VALVE
DESCRIPTION
1. Push nozzle
2. Main gas outlet
3. Main gas inlet
4. Thermocouple connection
1
2
4
3

AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.
Follow steps 1-4 in LP -NG conversion in this
manual.
Minimum Air Shutter Opening:
Fully Closed
NG
Fully Open
LP
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1/2 psig. (3.45 kPa). Disconnect piping
from supplied regulator at pressures over 1/2 psig.
Note: To properly check the inlet pressure, use
the regulator pressure tap (see P.15).
1. Make sure the valve is in the "OFF" position.
2. Loosen the pressure tap, turning counterclock-
wise with a 1/8" wide fl at screwdriver.
3. Attach manometer to pressure tap using a 5/16"
ID hose.
4. Light the unit (see Lighting instructions).
5. The pressure check should be carried out with
the unit burning and the setting should be within
the limits specifi ed on the safety label.
6. When fi nished reading manometer, turn off the
gas valve, disconnect the hose and tighten the
screw (clockwise) with a 1/8" fl at screwdriver.
Note: Screw should be snug, but do not over
tighten.