Advertisement

Quick Links

Models:
BCOL-18,24,30NG
BCOL3-18,24,30NG
For use with Natural gas only.
Check with your local building code agency before you begin installation to ensure compliance with local codes, including
the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need
clarification of any of the instructions contained here, contact the Technical Services Dept., Firegear LLC.,. 888-220-4333.
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
In the Commonwealth of Massachusetts:
Firegear, LLC., -IM-138 2/2012
Installation and service of this
appliance should be performed by
qualified personnel. Firegear LLC.,.
suggests NFI certified or factory-
trained professionals, or technicians
supervised by an NFI certified
professional.
Leave this manual with
party responsible for
use and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
Keep children away.
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high
temperatures.
Keep clothing, furniture, draperies and other
combustibles away.
This appliance must be installed by a licensed plumber
or gas fitter.
The chimney flue damper, when used with gas logs, will
be welded open or completely removed.
A CO detector shall be installed in the room where the
appliance is installed.
Installation
Instructions


Advertisement

Table of Contents
loading

Summary of Contents for Firegear BCOL-18NG

  • Page 1 Check with your local building code agency before you begin installation to ensure compliance with local codes, including the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarification of any of the instructions contained here, contact the Technical Services Dept., Firegear LLC.,. 888-220-4333. CAUTION...
  • Page 2: Homeowner Reference Information

    Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Firegear LLC.,. gas log set—an The information contained in this owner’s manual, unless elegant and clean alternative to burning wood. The Firegear noted otherwise, applies to all models and gas control LLC.,.
  • Page 3: Appliance Certification

    C. Important! • Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Firegear LLC.,. • Do not remove any of the attached metal plates, which recommends that NFI or CSIA certified professionals, or contain important safety and operating information.
  • Page 4: Gas Pressure

    (CO). CO (a poisonous gas) is tasteless, odorless, colorless and undetectable without proper equipment. • Refer to Table 3 to determine minimum fireplace opening requirements before proceeding. Firegear, LLC., -IM-138 2/2012...
  • Page 5: Inspect The Appliance And Components

    “F. Gas Pressure” to check for gas leaks. achieved using Table 3. See Figure . Ensure the gas type provided in the fireplace coincide with the gas type marked on the tag. Figure 1 Measure Firebox Firegear, LLC., -IM-138 2/2012...
  • Page 6 Note: For best results, do not pack down the rock wool. property damage or personal injury. The placement of rock wool can have an effect on flame pattern and may need to be adjusted to achieve a desired appearance. Firegear, LLC., -IM-138 2/2012...
  • Page 7: Cleaning And Maintenance Instructions

    After burning, the logs become fragile. Take care in • If necessary, seek expert advice. Do not operate this handling. appliance. Firegear, LLC., -IM-138 2/2012...
  • Page 8 (Located in wall or floor near fireplace) (Place lit match in ember bed before turning on valve) Valve Valve Key Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev B • 12/05 Firegear, LLC., -IM-138 2/2012...
  • Page 9: Frequently Asked Questions

    We recommend any soot build up be removed periodically using a product designed for gas log soot removal. Can I add a remote control to my log set after it has been installed? Firegear, LLC., -IM-138 2/2012...
  • Page 10: Replacement Parts

    BCOL-3-18,24 & 30 Description of Part 18in. 24 in. 30 in. Qty. Burner Pan/Grate Assembly BPA-300-8 BPA-300-24 BPA-300-30 Burner Pan/Grate Assembly (3 Tier Only) BPA-300-33 BPA-300-35 BPA-300-40 Gas Line Connector FT-8 FT-24 FT-30 Damper Clamp 0-065 0-065 0-065 Firegear, LLC., -IM-138 2/2012...

This manual is also suitable for:

Bcol-24ngBcol-30ngBcol3-18ngBcol3-24ngBcol3-30ng

Table of Contents