Utility Connections - Blodgett COS-6 Installation, Operation And Maintenance Manual

Combi-oven/steamer
Hide thumbs Also See for COS-6:
Table of Contents

Advertisement

Available languages

Available languages

Installation

Utility Connections

COLD WATER CONNECTION
Connect the appliance to quality water via a pres-
sure hose with 3/4" couplings. A shut off valve is
to be provided adjacent to the oven.
3/4" Coupling
Appliance
Solenoid
Washer
Figure 2
Water must meet the following minimum require-
ments:
Total Dissolved Solids (TDS) content will not ex-
D
ceed 30 parts per million.
Water PH must be 7.0 or higher
D
WARNING!!
The use of poor quality water will invali-
date your warranty.
1/2" appliance hose
with 3/4" hose fittings.
DRAIN CONNECTION
The Drain Vent assembly, included with the unit,
and a 2" (5 cm) copper pipe with standard drain
pitch, must be run to an open drain or connected
to a standpipe equipped with a vent.
NOTE: The waste water can also be directed to a
nearby floor drain. Flexible hose which al-
lows trapped water to accumulate in
sagged runs must be avoided.
WARNING!!
Failure to install the drain kit provided will
invalidate your warranty.
To Drain
A 24" (61 cm) long standpipe must be connected
to the DWV. This allows the escaping water vapor
to exit above the inlet louvers on the back panel.
Breather Vent
Plumber Installed
Connection
Tee, Hose and Clamps
Plumber Installed
Connection To Drain
8
2" (5 cm) Drain
(Customer Supplied)
Figure 3
Figure 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cos-101sCos-101

Table of Contents