Installation; Owner's Responsibilities - Blodgett COS-6 Installation, Operation And Maintenance Manual

Combi-oven/steamer
Hide thumbs Also See for COS-6:
Table of Contents

Advertisement

Available languages

Available languages

1. Oven(s) are uncrated, stacked (if applies) and
put in place.
NOTE: Please refer to Leg Attachment and
Stacking Addendum.
2. The owner/operator must have the following
plumbing and electrical requirements met and
installed.
NOTE: Refer to the Utility Connection infor-
mation provided.
Water
Water Pressure (min/max)
Cold Water Connection
Water Regulator Setting
Drainage
Drain Connection
Avg Water Drain Temp.
Electrical
By
y
Steam
Mode
M d
Hot Air
Combi
Blower Motor
PLUMBING
ELECTRICAL
COS-6
9.4 kw
Amp/line (max)
3
1
Volt
Phase
Phase
208
26
45
240
23
40
9kw
9kw
9kw
.33 HP / .4 kW

Installation

Owner's Responsibilities

WARNING!!
Improper installation, adjustment, alter-
ation service or maintenance can cause
property damage, injury or death. Read
the installation, operation and mainte-
nance instructions thoroughly before
installing or servicing this equipment.
40 PSI min / 50 PSI max
3/4" Hose Fitting, 3/8" ID hose minimum
35 PSI static
Atmospheric Vented Drain
2" Copper
Approximately 122_F / 50_C
COS-101
18.5 kw
Amp/line (max)
3
1
Volt
Phase
Phase
208
52
89
240
45
77
480
23
N/A
18kw
18kw
18kw
.5 HP / .5 kW
5
COS-101S
18.5 kw
Amp/line (max)
3
1
Volt
Phase
Phase
208
52
89
240
45
77
480
23
N/A
18kw
18kw
18kw
.5 HP / .5 kW

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cos-101sCos-101

Table of Contents