5. Operation Errors
Pressure sealer bolt release
The pressure sealer bolts on the machine not only allow you to recover from severe form
mishandling situations, they also provide accurate sealing pressure. The pressure on the
sealing rollers can be relieved then reset to the original factory setting in the event
mishandled forms lodge between the sealing rollers, stopping the machine processing.
1.
Unplug the power cord from the wall outlet.
2.
Remove the top cover and first folding plate.
3.
Using the 8mm allen key provided, turn the four adjustment screws
anticlockwise to relieve the sealing roller pressure. (Behind the front panel
beneath the in-feed bed.)
Figure 14: Relieving the sealing roller pressure
4.
Install the top cover, reconnect the power and switch the machine on.
Page 34
PS 600
22-01-03 Iss. B.