P010 - P013: Change Point Frequency/Change Point Voltage - Panasonic VF100 Instruction Manual

Table of Contents

Advertisement

P010£ºchange point frequency 1
P011£ºchange point voltage 1
P012£ºchange point frequency 2
P013£ºchange point voltage 2
Used to set change points 1 and 2 set with 3C mode in "P005: V/F pattern".
(These parameters are valid only when parameter P005 is set to "3C".)
[Parameter P010: change point frequency 1]
Data setting range (Hz)
[Parameter P011: change point voltage 1]
Data setting range (%)
[Parameter P012: change point frequency 2]
Data setting range (Hz)
[Parameter P013: change point voltage 2]
Data setting range (%)
Note
•E
Read carefully details on "P005: V/F pattern" before setting.
•E
If change point frequencies1 and 2 are set to be higher than base frequency, change point
frequencies 1 and 2 will operate according to setting value of base frequency.
•E
If change point frequency 2 is set to be lower than change point frequency 1, change point
frequency 2 will operate according to setting value of change point frequency 1.
•E
When setting "P007: torque boost level", if change point voltage 1 and 2 is set to be lower than
torque boost level, change point voltage 1 and 2 will operate according to setting value of
torque boost level.
•E
If change point voltage 2 is set to be lower than change point voltage 1, change point voltage
2 will operate according to setting value of change point voltage 1.
70
0.5 to 400.0
100
Output
voltage
0 to 100
(%)
0.5 to 400.0
0 to 100
Max. output frequency (P008)
Base frequency (P009)
Change point
frequency 2 (P012)
Change point
frequency 1
(P010)
Change point
voltage 1 (P011)
0
Output frequency (Hz)
Related
parameters
Change point
voltage 2
(P013)
P005, P100
¡«
P007
P009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf100

Table of Contents