P007£ºtorque boost level
Used to set a torque boost level that best fits the load characteristics. A larger value causes a
higher output voltage and stronger boost.
Data setting range (%)
[Constant torque mode]
Output
100
voltage
(%)
Boost level
0
Output
frequency(Hz)
£¼Method to boost torque at low speed£¾
If larger torque is required at low speed, value of torque boost level can be set to larger data.
Increasing output voltage to boost torque.
Note
•E
If the boost level is too high, an overcurrent fault, overload fault or motor overheating could occur
or the noise could increase.
•E
The motor current will increase when the value of boost level is increased. Carefully consider the
settings for "P016: electronic thermal select "and "P017: thermal current setting".
•E
Under control of vector (P129= "1"), torque boost level is invalid.
68
0 to 40
[Square torque mode]
Base
frequency
Output
100
voltage
(%)
Boost level
0
Output
frequency(Hz)
Related
parameters
Base
frequency
¡«
P005
P013
P016, P017