12-10. About Data Type

For the data for monitoring or setting, the displayed data of the inverter may differ from the
transmission data, so transmission data should be used as the data to be used for communication.
Calculate the transmission data using the following table of the data type.
Data type
1
Displayed data and transmission data is the same.
Data in 0.1 unit
2
(Transmission data) = (Displayed data) ¡Á10
Data in 0.01 unit
3
(Transmission data) = (Displayed data) ¡Á100
"P005: V/F mode" data
4
Displayed data:
Transmission data: 0
"P032: DC brake level" and "P035: DC brake level during forward / reverse run operation" data
5
(Transmission data) = (Displayed data) /5
"P092: Output RY function select" data
6
Displayed data:
Transmission data: 0 ¡« 10 11 ¡« 21
"P103: Bias frequency setting", "P126: 2nd bias frequency setting" and
"P134: Slip compensation frequency" data
7
(Transmission data) = (Displayed data) ¡Á10 + 1000
"P106: PID control mode" data
Displayed data:
8
Transmission data:
"P128: Carrier frequency" data
9
Displayed data:
Transmission data:
"P130: Motor capacity" data
10
Displayed data:
Transmission data:
"P131: No. of motor poles" data
11
Displayed data:
Transmission data:
"P137: Communication speed setting" data
12
Displayed data:
Transmission data:
194
Relationship between displayed data and transmission data
50 60 FF 3C
1
2
0 ¡« 10
0 1 2 3 A0 A1 A2 A3
0 1 2 3
0.8 1.1 1.6 2.5 5.0 7.5 10.0
0
1
0.4
0.7
2
2
4
0
1
48
96
4
5
3
r0 ¡« r10
4
5
6
7
2
3
4
5
1.5
2.2
3.7
3
4
5
6
6
2
192
384
6
7
6