Mbs (Main Bang Suppression); Target Level (Target Detection Level); System Menu; I/O Setup - Koden MDC-1840BB Operation Manual

Color radar
Table of Contents

Advertisement

Chapter 6
MDC-1840BB/1841BB/1860BB/1810BB/1820BB Series
Using The Menu
Select a desired level by the Joystick and press the ENT key to fix the entry.
RAIN MANUAL: This function is used to preset the reference receiver Anti-Clutter
Rain in MANUAL mode. Once set, the Anti-Clutter Rain will be controlled with
reference to the preset level. Select a desired level by the Joystick and press the ENT
key to fix the entry.

6.3.2.6 MBS (Main Bang Suppression)

Indication
MBS
This function is used to minimize the center sun shown on the radar screen caused by
the split of the transmitting energy generated by the magnetron (transmitting tube).

6.3.2.7 TARGET LEVEL (Target Detection Level)

Indication
TARGET LEVEL
This function is used to set the signal level to be supplied to the ATA system. Use the
following procedure to select a signal level.
(1) Highlight the TARGET LEVEL. The signal level increases in ascending order.
(2) Press the ENT key to set the ready to select status.
Press the Joystick up or down to select an appropriate level and press the ENT key to
set up the level.

6.4 SYSTEM MENU

The SYSTEM menu has I/O SETUP, SYS SETUP, and BITE functions. Details of each
function is as follows:

6.4.1 I/O SETUP

This function is used to select the data source supplied from a speed sensor and a
bearing sensor.
NOTE:
This menu is protected from ordinary operations. To use this function, turn off the
radar first. Press and hold the MODE key and turn the radar on again. When the standby
condition is established, turn the radar on to enter the following menu functions.
6-14
Meaning
Main Bang Suppression
Meaning
Target Detection Level
Operation Manual
Selection
0 to 99
Selection
1 to 8
93142122-07