Cpa Alarm Limit; Data Indication - Koden MDC-1840BB Operation Manual

Color radar
Table of Contents

Advertisement

MDC-1840BB/1841BB/1860BB/1810BB/1820BB Series
Using The Menu
Indication
TRUE (REL) VECT

6.1.7 CPA Alarm Limit

This function is used to set up the warning limit at which the CPA and TCPA alarms
are activated. Use the following procedure to set up.
(1) Highlight the item and press the ENT key.
(2) Move the Joystick up or down to select the value and press the ENT key.
(3) Setting ranges for CPA and TCPA are as follows:
ATA CPA: 0.00 NM to 19.9 NM.
ATA TCPA: 1 Minute to 63 min.
AIS LIM CPA: 0 NM to 19.9 NM
AIS TCPA: 1 to 63 min.
Indication
LIM CPA
TCPA

6.1.8 Data indication

The following data are shown in the data window.
------------------------------------------------------------------
EPA/ATA DATA
TARGET ID
AGE
CPA
TCPA
CSE/COG
STW/SOG
RNG
T BRG
-------------------------------------------------------------------
AIS DATA
LIM
TARGET ID
93142122-07
Meaning
Vector Indication Time
Meaning
Limit for CPA (NM)
Limit for Time to CPA (Min.)
Plot Mode
(Select with DISP/NAV/PLOT MODE menu. ATA: option)
ID for Operating Target
EPA Life
Closest Point of Approach
Time to CPA
Course/Course Over Ground
Speed Through Water/Speed Over Ground
Range
True Bearing
(ON/OFF with DISP/NAV/AIS menu)
Indicating Range
AIS data will be displayed inside the range of LIM setting.
Target ID for Data Indication -------- 1 to 64
Set the ship's ID to data display.
Operation Manual
Selection
OFF, 30SEC, 1MIN,
3MIN, 6MIN, 12MIN,
30MIN, 60MIN
Selection
0 to 19.9 (NM)
1 to 63 (Min.)
----------- 1.0 to 20.0 (NM)