3.2.4. Taking the saved settings into use

1. Select MEMORY by pressing the button.
2. Select memory channel by pressing CH button.
3. Start welding.

3.2.5. Remote controlling memory channels

Memory channels are selected by pressing simultaneously both REMOTE and CH button. With
the remote control you can recall saved settings on memory channels.

3.2.6. Set-up functions

For modifying functions of panels a so called Setup state is included. This state is entered by
pressing the Remote (setup) button longer than normally. Exit is performed in the same way. You
can select the function (see list below) by pressing the arrow buttons and then change the setting
by turning the panel potentiometer.
Display
Function
A1
Upslope with constant time setting /
gradient (steepness) setting
A2
Downslope with constant time setting /
gradient (steepness) setting
A3
TIG antifreeze off / on
A4
MMA antifreeze off / on
A5
MMA hot start pulse non adaptive / adaptive
A6
Downslope cut off on / off
A7
MMA no load voltage 80V / 40V
A8
2T downslope normal / cuts off by short switch action
A9
Tacking automatics off / on
A10
Current at arc start steep / slightly sloped
A11
Downslope linear / non linear
A12
MMA -TIG method selection with remote control
off /on
A13
Search arc off / on
A14
Possibility to current freezing during
downslope off/ on
A15
Control of channels with torch up-down off / on
A16
Control of current with torch up-down is always active /
active only when selected with remote button
A17
Not in use in Mastertig 2000 MLS
A18
Modified selection of cut off in MTL and MTM panels. For
downslope, press start switch and keep it down
(4T and Minilog)
A19
Not in use in Mastertig 2000 MLS

3.3. STORAGE

The machine must be stored in a clean and dry room. Protect the machine from rain and keep it
away from direct sunshine in places where temperature exceeds +25 °C.
14 – MASTER MLS™ 1600, MASTERTIG MLS™ 2000 / 0530
Factory setting
0
constant time
0
constant time
1
on
1
on
0
non adaptive
0
on
0
80 V
0
normal
0
off
0
steep
0
linear
0
off
1
on
0
off
0
off
0
always active
0
normal
© KEMPPI OY