5. TECHNICAL DATA

Master MLS™ 1600, Mastertig MLS™ 2000
Mains voltage
Rated power
Connection cable/fuse
Welding current range
Max welding voltage
Electrode sizes to be
welded
Welding current control
Open circuit voltage
Efficiency
Power factor
Open circuit power
Storage temperature
range
Operation temperature
range
Temperature class
Degree of protection
External dimensions
Weight
*) With 16 A fuse max. welding current is 150 A. If this exceeded a 20 A fuse and plug are
needed.
The products meet the conformity requirements of CE-marking.
© KEMPPI OY
1~ 50/60 Hz
35% ED MMA
60% ED MMA
100% ED MMA
30% ED TIG
60% ED TIG
100% ED TIG
MMA
TIG
length
width
height
TIG power source
MMA power source
MASTER MLS™ 1600, MASTERTIG MLS™ 2000 / 0530 – 17
230 V - 10 %...+ 10 %
160A / 7,1 kVA
140A / 5,8 kVA
120A / 4,8 kVA
200A / 6,5 kVA
150A / 4,2 kVA
130A/ 3,4 kVA
3 x 2,5S - 3,3 m/16 A delayed *)
10 A/20,5 V...160 A/26,4 V
5A/10,0 V...200 A/18,0 V
36 V / 160 A
Ø1,5...4,0 mm
stepless
80 V (tai 40 V)
80 % (160 A/26,4 V)
0,75 (160 A/26,4 V)
approx. 10 W
-40 ... +60 °C
-20 ... +40 °C
H (180 °C / B (130 °C)
IP 23 C
410 mm
180 mm
390 mm (body 330 mm)
15 kg
14 kg