Kemppi MLS 2300 ACDC Operating Manual

Kemppi MLS 2300 ACDC Operating Manual

Mastertig
Hide thumbs Also See for MLS 2300 ACDC:

Advertisement

MasterTig
MLS 2300 ACDC
EN
Operating manual • English
FI
Käyttöohje • Suomi
SV
Bruksanvisning • Svenska
NO
Bruksanvisning • Norsk
DA
Brugsanvisning • Dansk
DE
Gebrauchsanweisung • Deutsch
NL
Gebruiksaanwijzing • Nederlands
FR
Manuel d'utilisation • Français
ES
Manual de instrucciones • Español
PL
Instrukcja obsługi • Polski
RU
Инструкции по эксплуатации • По-русски
ZH
操作手册 • 中文
PT
Manual de utilização • Português
IT
Manuale d'uso • Italiano

Advertisement

Table of Contents
loading

Summary of Contents for Kemppi MLS 2300 ACDC

  • Page 1 MasterTig MLS 2300 ACDC Operating manual • English Käyttöohje • Suomi Bruksanvisning • Svenska Bruksanvisning • Norsk Brugsanvisning • Dansk Gebrauchsanweisung • Deutsch Gebruiksaanwijzing • Nederlands Manuel d’utilisation • Français Manual de instrucciones • Español Instrukcja obsługi • Polski Инструкции по эксплуатации • По-русски...
  • Page 3 OperaTing Manual english...
  • Page 4: Table Of Contents

    COnTenTs preFaCe ..........................General .
  • Page 5: Preface

    This user manual contains important information on the use, maintenance and safety of your Kemppi product. The technical specifications of the device can be found at the end of the manual. Please read the manual carefully before using the equipment for the first time.
  • Page 6: Installation

    insTallaTiOn reMOval FrOM paCkaging The equipment is packed in durable packages designed especially for it. However, it is necessary to check the equipment before using it to make sure that the equipment or any part of it has not got damaged during transportation. Also check that the delivery corresponds to your order and that you have received all necessary instructions for installing and operating the equipment.
  • Page 7: Installation Of The Panel

    Front of machine Markings for (+/–) poles on the machine front are embossed. Function panel Remote control connector rear of machine TIG torch control connector Mains switch Shield gas and current connector for Snap connector for gas TIG torch (+) connector for electrode holder (–) connector for earth cable Installing gas-cooled torch Installing water-cooled torch...
  • Page 8: Mains Connection

    Cooling liquid is injurious! Avoid also contact with skin or eyes. In case of injury, seek for NOTE! medical advice. Cooling unit Mastercool 20 together with TIG torch Kemppi TTC-W range enables TIG welding with water-cooled torch. The cooling unit is installed beneath the power source with screws. Electrical connections are on the bottom of power source.
  • Page 9 installation of cooling unit: electrical connection for the cooling unit: 230 V Control connector Equipment earth Only an authorised electrician is allowed to install electrical connection! NOTE!
  • Page 10: Shield Gas

    8 – 10 l/min. If the gas flow is not suitable the welded joint will be porous. Spark ignition becomes more difficult if the gas flow is too high. Contact your local Kemppi dealer for choosing gas and equipment.
  • Page 11: Operation

    OperaTiOn Welding in places presenting an immediate fire or explosion hazard is forbidden! NOTE! Welding fumes may cause injury, take care of sufficient ventilation during welding! NOTE! welding prOCesses 3.1.1 MMa welding With Mastertig MLS™ ACDC power sources you can use all electrodes suitable for direct and alternating current welding between current limits of the power source.
  • Page 12: Synergetic Pulsed Tig Welding

    Before welding starts, welding settings suitable for the work piece are chosen with the function panel. The Kemppi Multi Logic System, MLS™, allows you to select the function panel based on the purpose of use: the ACS panel for AC TIG welding with basic functions, or the ACX panel with pulsed TIG, 4T-LOG or MINILOG control of welding current and memory channel functions.
  • Page 13 aCs welding panel – basic functions 12. 13. Selection button and indicators for TIG welding and current type Selection button and indicators for MMA welding and current type Current and voltage display, display for other welding parameters QUICK SETUP button for MMA and TIG adjustments (e.g. balance adjustment) Selection of the torch switch function 2T/4T HF/contact TIG (WATER FILL) button Remote control selection button (setting the limits for the adjustment range: LO/HI)
  • Page 14: Tig Welding

    1. dynamics (“arc” –9 … 0 … +9) You will see the numerical value corresponding to the MMA dynamics in the display. Factory setting for all electrode types is zero. You can change the value by turning the pulse potentiometer. If numerical value is adjusted negative (-1...-9) the arc is softened, and the amount of spatter decreases when welding at the upper end of the recommended current range of the electrode.
  • Page 15: Remote Control

    3. MiX Tig (mixed current aC/dC-) With mixed current frequency and balance of alternating current are determined by adjustments made for AC-current. Adjust by choosing sections 4. – 5. if needed. The following QuiCk seTup parameters can be adjusted: AC-time (AC 10 ... 90 %, factory setting 50 %) Cycle time (CYc 0.1 ...
  • Page 16 welding panel aCX – pulsed Tig and MinilOg function with memory 4T-LOG and MINILOG function selections Search arc 5 – 90 % of welding current Start-current 80 – 150 % Minilog-current 10 – 150 % of welding current Tail arc 5 – 90 % of welding current Selection for spot, synergetic quick pulse and long pulse Spot time 0,0 –...
  • Page 17: Saving Welding Settings

    Minilog When torch switch is pressed gas flow starts. When you release the torch switch current goes through upslope to Hot Start or Soft Start -current depending on adjustments and by pressing shortly again to welding current. After another short press it goes to Minilog operation, and you can select from two current levels: the welding current and the Minilog current.
  • Page 18: Adopting The Saved Settings

    3.2.4 adopting the saved settings Select MEMORY by pressing the button. Select memory channel by pressing the CH button. Start welding. 3.2.5 remote control memory channels Memory channels are selected by pressing simultaneously both REMOTE and CH button. With the remote control you can retrieve saved settings on memory channels 1-5. The selected channel is marked with a dot.
  • Page 19: Setup-Functions

    seTup-FunCTiOns SETUP-function Display *C = Common: applies to all memory channels Factory setting with a grey background Upslope current dependency (*C) The upslope time is determined by the current. The upslope time remains as set. Downslope current dependency (*C) The downslope time is determined by the current (the user may set the slope gradient).
  • Page 20: Error Codes

    Only an authorised electrician may repair the machine. NOTE! 4.1.2 service contract KEMPPI service workshops make special service contracts with customers about regular maintenance. All parts are cleaned, checked and if necessary, repaired. Also the operation of welding machine is tested.
  • Page 21: Troubleshooting

    The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health.
  • Page 22: Ordering Numbers

    Ordering nuMbers Power source Mastertig MLS™ 2300 ACDC 6162300 Panels 6162805 6162804 Cabels Welding cable 16 mm² 6184103 Welding cable 25 mm² 6184201 Welding cable 25 mm² 10 m 6184202 Welding cable 35 mm² 6184301 Earth cable 16 mm² 6184113 Earth cable 25 mm²...
  • Page 23: Technical Data

    TeCHniCal daTa Power source Mastertig MLS™ 2300 ACDC Connection voltage 1~230 V –15%…+15% Rated power 40% ED TIG 230 A 5,7 kVA 60% ED TIG 200 A 4,8 kVA 100% ED TIG 170 A 3,9 kVA 40% ED MMA 180 A 6,0 kVA 60% ED MMA 150 A...
  • Page 24 Power source and cooling unit Operating temperature range -20 °C ..+40 °C Storage temperature range -20 °C ..+60 °C EMC class Degree of protection IP 23 C Recommended generator Smin 8 kVA...
  • Page 26 78681 EPONE CEDEX myynti.fi@kemppi.com info.ru@kemppi.com FRANCE Tel +33 1 30 90 04 40 KEMPPI SVERIGE AB KEMPPI, TRADING (BEIJING) COMPANY, Telefax +33 1 30 90 04 45 LIMITED Box 717 sales.fr@kemppi.com Room 420, 3 Zone, Building B, S-194 27 UPPLANDS VÄSBY No.12 Hongda North Street,...

This manual is also suitable for:

Mastertig mls 2300 acdc

Table of Contents