System-Event Log - IBM x3200 M3 7327 Service Manual

Hide thumbs Also See for x3200 M3 7327:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3200 M3 Types 7327 and 7328," on page 133 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical
information, hints, tips, and new device drivers or to submit a request for information.
Error code
Description
3818003
Core Root of Trust Measurement (CRTM)
flash lock failed
3818004
Core Root of Trust Measurement (CRTM)
system error
3818005
Current Bank Core Root of Trust
Measurement (CRTM) capsule signature
invalid
3818006
Opposite bank CRTM capsule signature
invalid
3818007
CRTM update capsule signature invalid
3828004
AEM power capping disabled

System-event log

The system-event log contains messages of three types:
Information
34
System x3200 M3 Types 7327 and 7328: Problem Determination and Service Guide
Information messages do not require action; they record significant
system-level events, such as when the server is started.
Action
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Switch the server firmware bank to the backup
bank (see "Starting the backup server firmware"
on page 229).
2. Run the Setup utility, select Load Default
Settings, and save the settings.
3. Switch the bank back to the primary bank.
4. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Check the settings and the event logs.
2. Make sure that the Active Energy Manager feature
is enabled in the Setup utility. Select System
Settings -> Power -> Active Energy -> Capping
Enabled.
3. Update the server firmware to the latest level (see
"Updating the firmware" on page 221).
4. Update the IMM firmware to the latest level (see
"Updating the firmware" on page 221).