IBM x3200 M3 7327 Service Manual page 127

Hide thumbs Also See for x3200 M3 7327:
Table of Contents

Advertisement

Table 5. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3200 M3 Types 7327 and 7328," on page 133 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Message
number
Component
201-801-xxx
Memory
201-802-xxx
Memory
Test
State
Memory Test
Aborted
Memory Test
Aborted
Description
Action
Test canceled: the
1. Turn off and restart the system.
system UEFI
2. Run the test again.
programmed the
3. Make sure that the server firmware is
memory controller
with an invalid
at the latest level. The installed
CBAR address
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see "Updating the
firmware" on page 221.
4. Run the test again.
5. If the failure remains, go to the IBM
Web site for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Test canceled: the
1. Turn off and restart the system.
end address in the
2. Run the test again.
E820 function is
3. Make sure that all DIMMs are
less than 16 MB.
enabled in the Setup utility.
4. Make sure that the server firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see "Updating the
firmware" on page 221.
5. Run the test again.
6. If the failure remains, go to the IBM
Web site for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
107