1.7

Removal of Compressor

Procedure
Step
Open upward the sound
1
insulation for the
terminal cover.
2
Remove the terminal
cover with a flat
screwdriver.
Disconnect the
3
terminals of the
compressor.
Removal Procedure
Warning
Be sure to commence the disassembling work after 10 minutes or
more elapsed from all power supplies have been turned off.
Procedure
Sound insulation for the terminal cover
Terminal cover
Preparation
Remove the outer panels,
electrical components, and
peripheral equipments.
(R9264)
(R9265)
Red: U
(R12985)
Outdoor Unit
Points
Blue: W
White: V
451