Daikin Super Multi Plus E-Series FTXG25EV1BW Service Manual page 125

Table of Contents

Advertisement

SiBE18-821_C
2. Motions (for example: in cooling)
Human detection
signal
(From area A or B)
Target temperature
INTELLIGENT EYE
lamp
Remote controller
INTELLIGENT EYE
button
Operation
Fan speed ( 1)
3. Airflow direction in 2-area INTELLIGENT EYE operation
1. Detection signal ON in both area A and B: Shift the airflow direction to area B (left side)
2. Detection signal ON in area A: Shift the airflow direction to area B (left side)
3. Detection signal ON in area B: Shift the airflow direction to area A (right side)
4. Detection signal OFF in both area A and B: No change
* When the detection signal is OFF for 20 minutes in both area A and B, the unit starts energy
Others
Function
within 20
minutes
ON
OFF
RESET.
ON
OFF
ON
OFF
ON
OFF
Set speed
OFF
When the microcomputer does not have a signal from the sensor in 20 minutes, it judges
that nobody is in the room and operates the unit in temperature shifted from the target
temperature. (Cooling / Dry : 2°C higher, Heating : 2°C lower, Auto : according to the
operation mode at that time.)
1 In case of FAN mode, the fan speed reduces by 60 rpm.
Detection method: The opposite area of detected area is set as the target direction.
Left
saving operation.
For dry operation, you cannot set the temperature with remote controller, but internally the
target temperature is shifted by 2°C.
20 min.
Indoor unit
Human
Area A
Area B
Indoor Unit Control (RA Models)
20 min.
Set speed
Wall
Top view
Right
(R3853)
(R12183)
113

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super multi plus e-series ftxg35ev1bwSuper multi plus e-series ftxg25jv1bwSuper multi plus e-series ftxg35jv1bwSuper multi plus e-series ctxg50jv1bwSuper multi plus e-series bpmks967b2bSuper multi plus e-series bpmks967b3b ... Show all

Table of Contents