Daikin CTXG50EV1BW User Manual

Wall mounted, inverter controlled unit
Hide thumbs Also See for CTXG50EV1BW:

Advertisement

technical data

CTXG-EV1BW_EV1BS
Wall Mounted,
Inverter Controlled Unit
Split
Sky Air

Advertisement

Table of Contents
loading

Summary of Contents for Daikin CTXG50EV1BW

  • Page 1: Technical Data

    technical data CTXG-EV1BW_EV1BS Wall Mounted, Inverter Controlled Unit Split Sky Air...
  • Page 2: Table Of Contents

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS TABLE OF CONTENTS CTXG-EV1BW_EV1BS Features ............. 2 Specifications .
  • Page 3: Features

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS Features W _ E U n i V 1 B o o r G - E 1 0 A I n d C T X R - 4 • State of the art design: sleek, compact and stylish outlook •...
  • Page 4: Specifications

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS Specifications 2-1 FOR INDOOR UNITS ONLY CTXG50EV1BW CTXG50EV1BS Nominal Input Cooling 0.030 0.030 Heating 0.030 0.030 2-2 TECHNICAL SPECIFICATIONS CTXG50EV1BW CTXG50EV1BS Casing Colour Mat Crystal White Mat Crystal Silver Dimensions Packing Height Width...
  • Page 5: Electrical Specifications

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS Specifications 2-2 TECHNICAL SPECIFICATIONS CTXG50EV1BW CTXG50EV1BS Piping Liquid (OD) Diameter connections (OD) Diameter 12.7 12.7 (OD) Drain Diameter (OD) Heat Insulation Both liquid and gas pipes Standard Item Installation manual Accessories Quantity Item...
  • Page 6: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS Dimensional drawing & centre of gravity 3 - 1 Dimensional drawing unit (mm) CTXG50E The mark (Y) shows piping direction Installation Required space Rear Air flow (indoor) 50 Min. Left Right (space for (Including mounting plate) maintenance) 50 Min.
  • Page 7: Centre Of Gravity

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS Dimensional drawing & centre of gravity 3 - 2 Centre of gravity CTXG-E 4D050964 • Split Sky Air • Indoor Units...
  • Page 8: Piping Diagram

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS Piping diagram CTXG50E Indoor unit Heat exchanger Thermistor on heat exchanger Cross flow fan Field piping Fan motor Field piping Refrigerant flow Cooling Heating 4D050924 • Split Sky Air • Indoor Units...
  • Page 9: Wiring Diagram

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS Wiring diagram 5 - 1 Wiring diagram CTXG50E Signal receiver Field wiring Infrared remote control Transmission circuit Outdoor Intelligent eye CAUTION sensor Note that operation will restart automatically if the main power supply is turned off and then back on again.
  • Page 10: Sound Data

    • Indoor Units • R-410A • CTXG-EV1BW_EV1BS Sound data 6 - 1 Sound pressure spectrum CTXG50E (Cooling) CTXG50E (Heating) approximate threshold approximate threshold hearing for continuous hearing for continuous noise noise 3D050972 Octave band center frequency (Hz) 3D050972 Octave band center frequency (Hz) NOTE NOTE Operation noise differs with operation and...
  • Page 12 Daikin Europe N.V. explicitly rejects any liability for any direct Daikin Europe N.V. is approved by LRQA for its Quality Daikin Europe N.V. is participating in the or indirect damage, In the broadest sense, arising from Management System in accordance with the ISO9001 EUROVENT Certification Programme.