Fan Motor Connector Check - Daikin Super Multi Plus E-Series FTXG25EV1BW Service Manual

Table of Contents

Advertisement

SiBE18-821_C

7.35.3 Fan Motor Connector Check

Check No. 03
(1) Turn the power supply off.
(2) With the fan motor connector disconnected, measure the resistance between each pin, then
Troubleshooting
make sure that the resistance is more than the value mentioned in the following table.
1 White
2 Orange
3 Brown
GND
4 Blue
5
6
7 Red
Measurement point
1 - 4
2 - 4
3 - 4
4 - 7
(R13657)
Troubleshooting for Outdoor Unit
Judgment
1 MΩ or more
100 kΩ or more
100 Ω or more
100 kΩ or more