Method Of Replacing Inverter's Power Transistors Modules - Daikin Super Multi Plus E-Series FTXG25EV1BW Service Manual

Table of Contents

Advertisement

Method of Replacing Inverter's Power Transistors Modules

10.Method of Replacing Inverter's Power Transistors
Modules
Check the power semiconductors mounted on the main PCB (A1P) with a multiple tester.
<Items to be prepared>
<Preparation>
Main PCB (A1P)
430
Multiple tester : Prepare the digital type of multiple tester with diode check function.
Turn OFF the power supply. Then, after a lapse of 10 minutes or more, make measurement
of resistance.
To make measurement, disconnect all connectors and terminals.
C –
C +
SiBE18-821_C
W
V
U
(R13060)