KVH Industries TracVision G8 Owner's Manual page 80

Lennox hearth satellite tv system user manual
Hide thumbs Also See for TracVision G8:
Table of Contents

Advertisement

Viewing the Calibration Score
The calibration score should be checked the first time you are
underway after installing the TracVision G8 and whenever
adjustments are made to vessel equipment that can affect the
sensor's accuracy.
Get Cal Score?
Yes
Next
ACC
MagEnv
CAL<#°
XXXX
Magnetic Environment
Accuracy
ACC
CAL<1°
Accuracy (ACC)
The ACC data indicates the sensor's degree of accuracy. Table 3-3
lists the five possible accuracy levels.
Magnetic Environment (MAGENV)
The MAGENV score (GOOD, OK, POOR, BAD) indicates the
quality of the installation location. If the quality is POOR or BAD,
the antenna may need to be moved to a more favorable magnetic
environment, or the source of magnetic interference needs to be
relocated.
Calibration Update Number (CAL #)
The CAL # indicates the number of times the sensor has
calibrated itself. It is used primarily to verify whether a new
calibration has been accepted by the system.
54-0198
Return
Proceed to "Clearing the
Calibration"
Cal#
#
Calibration Update
Number
MagEnv
Cal#
GOOD
3
Using the MCU Interface
Figure 3-24
Viewing Calibration Score
Figure 3-25
Sample Calibration Score Screen
Table 3-3
Possible Compass Accuracy Levels
ACC Score
Accuracy
º
<1
Better than 1
º
<2
Better than 2
º
<4
Better than 4
º
<8
Better than 8
BAD CAL
Poor cal
º
º
º
º
79