TracVision G8 Owner's Manual - Guide to Technical Information
Figure 5-40
Skew Motor Cable Connector
on PCB Module
Figure 5-41
Removing the LNB/
Feed Tube Assembly
#8-32 Screws
(x 4)
Figure 5-42
Skew Motor and Belt
118
3. Disconnect the skew motor cable from the PCB
module.
LIMIT SWITCHES
AZIMUTH/ROLL GYRO
INTERNAL SENSOR
ELEVATION GYRO
4. Remove the four #8-32 screws securing the
LNB/feed tube assembly to the reflector base (see
Figure 5-41). Withdraw the LNB/feed tube
assembly through the center hole in the reflector.
Motor Cable
Connector
Motor Hub
M3 Cap Screws
(x 4)
5. Using a 2.5 mm allen wrench, loosen (do not
remove) the four M3 cap screws securing the
motor to the bracket until the motor is free to slide
back and forth (see Figure 5-42). Slide the motor
toward the pulley to loosen the belt.
6. Roll the belt over the motor hub, then over the
pulley. Remove and discard the old belt.
7. Place the new belt around the pulley and around
the motor hub. Ensure that the teeth are on the
inside of the belt.
ELEVATION & AZIMUTH MOTORS
POWER
FUSE
SKEW MOTOR
Skew Motor
Cable Connector
Motor Cable
Pulley
Skew Belt
54-0198