Programming Manual References
None
Feature Guide References
None

Device Type

Selects the type of connected output device (for output ports only).
Value Range
Relay, Ringer
Maintenance Console Location
3.58 [1-1] Slot—OPB3 Card Property
Programming Manual References
None
Feature Guide References
1.17.9 External Relay Control
Input Signal Decision Time
Specifies the minimum duration of continuous input from the triggered sensor before the PBX recognises the
input and makes a sensor call.
Value Range
32 ´ n (n=2–255) ms
Maintenance Console Location
3.58 [1-1] Slot—OPB3 Card Property
Programming Manual References
None
Feature Guide References
1.17.8 External Sensor
Input Signal Detection Reopening Time
Specifies the length of time after the sensor has been triggered during which any further input from the sensor
will be ignored.
3.58 [1-1] Slot—OPB3 Card Property