Panasonic KX-TDE100 Programming Manual page 418

Ip-pbx
Hide thumbs Also See for KX-TDE100:
Table of Contents

Advertisement

3.50 [1-1] Slot—Port Property - DID Port
Maintenance Console Location
3.50 [1-1] Slot—Port Property - DID Port
Programming Manual References
None
Feature Guide References
None
Start Signal Type
Selects the type of the start signal.
Value Range
Immediate: Sends the dialled digits to the trunk when the First Dial Timer expires.
Wink: Sends the dialled digits to the trunk when the wink signal is received.
Maintenance Console Location
3.50 [1-1] Slot—Port Property - DID Port
Programming Manual References
None
Feature Guide References
None
CPC Detection Time—Out (DID), In (DID)
Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incoming trunk calls
before disconnecting the line. When None is selected here, the line will not be disconnected when a CPC
signal is not detected.
Value Range
None, 80 ´ n (n=2–75) ms
Maintenance Console Location
3.50 [1-1] Slot—Port Property - DID Port
Programming Manual References
None
Feature Guide References
1.11.10 Calling Party Control (CPC) Signal Detection