3.40 [1-1] Slot—Card Property - E1 type
Seizure ACK Wait Timer
Specifies the length of time that the PBX waits for the seizure ACK signal.
Value Range
0.5 ´ n (n=1–20) s
Maintenance Console Location
3.40 [1-1] Slot—Card Property - E1 type
Programming Manual References
None
Feature Guide References
None
LIU Send Option
Indicates the transmitting level (Transmit Pulse Amplitude) of LIU (reference only).
Value Range
Mode 1–Mode 8
Maintenance Console Location
3.40 [1-1] Slot—Card Property - E1 type
Programming Manual References
None
Feature Guide References
None
LIU Receive Option
Selects the receiving level (Receive Equalisation) of LIU.
Value Range
Automatic, 6 dB, 12 dB, 18 dB, 24 dB
Maintenance Console Location
3.40 [1-1] Slot—Card Property - E1 type