The Remote Control Fails To Control The Unit; While Playing A Dvd, A Burst Of Noise Is Heard, Elgar Plus Mutes And Changes Sample Rate; Cd Update; Cd Update Is Interrupted And Fails To Recover - DCS Elgar Plus User Manual

Dcs elgar plus stereo digital to analogue converter
Hide thumbs Also See for Elgar Plus:
Table of Contents

Advertisement

dCS Elgar Plus User Manual
dCS Ltd

The Remote Control fails to control the unit

While playing a DVD, a burst of noise is heard, Elgar Plus mutes and changes sample rate

CD Update

CD Update
CD Update
CD Update
is interrupted or fails
CD Update
CD Update
CD Update
CD Update
is interrupted and fails to recover
Manual filename: Elgar Manual v4.4x.doc
English version
The Remote Control is normally shipped with the batteries packed
separately for safety reasons. If you are using the Remote Control for the
first time, you must fit the batteries first – see page 59.
If the Remote Control has not been used for a long time or has gradually
lost range, the batteries should be replaced - see page 59.
If you have just replaced the batteries but the unit still does not work, check
that the batteries are fitted the right way around - see page 59. If two or
more batteries were fitted the wrong around, the Remote Control may be
permanently damaged. If this occurs, contact your dealer for advice.
For correct operation, there must be a clear line of sight between the
infrared transmitter at the end of the Remote Control and the infrared
receiver in Elgar Plus, located on the left hand side of the display. If the line
of sight is blocked (for example by a coffee table) the Remote Control may
operate erratically or not at all.
While the unit is displaying
fluctuating and this may temporarily disrupt the operation of the Remote
Control. Once the unit locks, normal operation will be resumed.
We have found that some DVDs have been compiled with tracks recorded
at different sample rates (e.g. 96kS/s & 48kS/s). There is no warning of this
sudden change in sample rate (this could be done by using the Non-Audio
flag or by changing the sample rate code in the data stream), so the DAC
tries to decode corrupted data momentarily before registering loss of sync,
muting and re-locking. The root cause of the problem is a lack of a formal
interface standard covering sample rates above 48kS/s. When a new
standard is agreed, Elgar Plus' software can be updated to comply with it.
This is unlikely to improve the situation with existing disks. Meanwhile, we
suggest you reduce the volume at the end of the track where a change
occurs and increase it when Elgar Plus displays a new sample rate.
If a software update from a dCS CD is interrupted, the original software
may be recovered by switching Elgar Plus off and on, then waiting a few
CD Update
minutes. See
If you are using an Upsampler or other device, ensure it is set to bit-for-bit
(Clone) mode.
If your CD player upsamples to 48kS/s or 88.2kS/s or adds dither (a few
types do this), the update program will reject the data. Use or borrow an
"ordinary" CD player.
It is just possible (but very unlikely) that the recovery will fail if the recovery
code was being over-written when the interruption occurred. If you are very
unlucky and this happens, ask your dealer for help. New software must be
loaded from an EPROM.
or
Locking
on page 30.
Page 68
Manual for Software Issue 4.3x
August 2005
..., the system timing is
Wait
email: more@dcsltd.co.uk
web-site: www.dcsltd.co.uk