do this:
do this:
TimeOut
TimeOut
TimeOut
TimeOut
– Menu Time Out Setting
do this:
do this:
do this:
do this:
PLL
PLL
PLL
PLL
- PLL Tracking bandwidth
do this:
do this:
Manual filename: Elgar Manual v4.4x.doc
English version
Applying the same
Using different settings for each input (Local volume, or
is useful where the average loudness (and so the preferred
changes from source to source.
To change this setting:
Open the Function Menu and step through until you reach the
display shows
Vol:Glob
Press the
button to choose one of these settings and wait for time out.
Select
If you find the 5 second time out period for the menu is too short, use this option
to change the time out period to 30 seconds.
Open the Menu and step through until the display shows Timeout.
Press the
button once and the display will show Normal.
Select
Press the
button again and the display will change to Long.
Select
Repeat this if you want to change back.
In slave mode, the PLL (Phase Locked Loop) synchronises Elgar Plus' internal
crystal clocks to the incoming data stream. The system runs through two
different modes while locking. The final mode (fine lock) has a very narrow
bandwidth which rejects jitter generated by the source. This is the normal PLL
setting and gives best results with a stable source. It takes about 6 seconds to
lock.
Some CD players (even some very expensive ones!) generate a high level of
jitter and this can cause Elgar Plus to intermittently lose fine lock and mute the
Outputs. This menu option forces the PLL to stay in a wide-band
Analogue
mode, allowing it to track larger variations in the source sample rate. In this
mode, the unit locks in less than 100 milliseconds.
To change the setting:
Open the Function Menu and step through until the display shows
PLL:
Wide.
Press the
button to change between these two settings. Select
Select
if you are having locking problems.
If you are using Elgar Plus in master mode or with a Master Clock, the PLL
should be set to PLL:Fine, otherwise the jitter improvement will be lost.
setting to all inputs
Volume
or Vol:Inp.
Page 25
Manual for Software Issue 4.3x
August 2005
(Global
volume).
specific). This
Input
Volume
Vol
page. The
PLL: Fine
PLL:Wide
email: more@dcsltd.co.uk
web-site: www.dcsltd.co.uk
setting)