Setup Menu (Mfr-39Ru); Ip Address[Ru]; Subnet Mask[Ru] - FOR-A MFR-1616 Operation Manual

Multi format routing switcher
Hide thumbs Also See for MFR-1616:
Table of Contents

Advertisement

5-5. Setup Menu (MFR-39RU)

The SETUP button enables you to use the setup menu.
The Setup menu has following sub menus. To select a submenu, turn the control knob to select
and press to confirm.
 Setup Menu Sub-menu List
Menu display
SETUP>IP ADDRESS[RU]
SETUP>SUBNET MASK[RU]
SETUP>PC-LAN[MU]<ENT>
SETUP>RU CONN ID
SETUP>RU CONNECT <ENT>
SETUP>BRIGHTNESS <ENT>
SETUP>BTN ASSIGN <ENT>
SETUP>VER/ALARM <ENT>
SETUP>REBOOT
SETUP>EXIT

5-5-1. IP ADDRESS[RU]

This menu allows you to change the IP address of remote control panels. The last 8 bits (the
th
4
byte) will be the unit ID.
SETUP>IP ADDRESS[RU]
192.168.001.100<ENT>
Turn the control knob to select a byte to be changed. The selected byte will be highlighted.
After changing the value, press the knob. The next byte will be highlighted to be changed.
SETUP>IP ADDRESS
192.168.001.100<ENT>
Pressing the control knob while the 4
and the changed IP address will be saved. Press the control knob again. The remote control
panel will restart, or a message appears to ask to restart the remote control panel. Select
YES and press the control knob to restart the remote control panel with the new IP address.
The saved IP address applies when the remote control panel restarts. Selecting NO
will necessitate a manual restart of the remote control panel to apply the new IP
address. The IP address must not be identical to the IP address of the MFR main unit
or other remote control panels.

5-5-2. SUBNET MASK[RU]

Displays the subnet mask setting in the Remote Control Unit.
SETUP>SUBNET MASK[RU]
255.255.255.000
Allows you to set the IP address for the remote control
panel. The last 8 bits will be the unit ID/
<ENT>
Displays the subnet mask setting in the Remote
<ENT>
Control Unit.
Displays the PC-LAN[MU] menu.
<ENT>
Allows you to set the ID to recognize remote control
panels connected to be used in conjunction.
Allows you to select whether to connect and use
multiple remote control panels.
Allows you to set the brightness for buttons and the
menu display.
Allows you to assign functions to buttons.
Assignments the same as in the Setting mode menu
can be performed.
Displays version and alarm information.
<ENT>
Allows you to reboot the unit.
<ENT>
Allows you to exit the Setup menu. The menu returns
to display the menu before entering the SETUP menu.
(The CANCEL button works the same.)
th
IMPORTANT
Description
byte is highlighted will highlight the whole IP address,
60
Reference
5-5-1
5-5-2
5-5-3
5-5-4
5-5-5
5-5-6
5-5-7
5-5-8
5-5-9
-

Hide quick links:

Advertisement

Table of Contents
loading