14. Conned the power cord to the wall receptacle or close wall
circuit breaker.
Heating element should never be energized without
shortening in the frypot, or damage to element could
result.
15. Replace the shortening in the fry-pot.
If either contactor is defective it must be replaced as follows:
I
WARNING
Remove electrical power supplied to the fryer, by
unplugging or opening the wall circuit breaker, or
electrical shock could result.
1. Remove only those wires directly connected to the
contactor being replaced. Label the wires.
2. Remove the two mounting screws on the base plate and
remove contactor.
3. Install the new contactor and tighten the two mounting
screws.
4. Connect the labeled wires to their respective positions.
5. Install the control panel.
connect power to the fryer and test the fryer for proper
operation.