Step 3
Place power switch in the OFF position, shut off power
at the fuse or breaker box. Failure to do so could result
in electrical shock.
1. Drain the shortening.
2. Remove the thermostat and high limit bulb holder from
the heating element inside the frypot.
3. Remove the heating element wires from the contactor.
Label each so it can be replaced in the same position on
the new element.
4. Slide the element spreaders to the center of the heating
element.
5. Remove the brass nut and washer, which secure the ends
of the element through the frypot wall.
6. Remove the heating element from the frypot by lifting the
far end and sliding it up and out toward the rear of the
frypot.
Always install new rubber 0 rings (2) when installing
heater elements.
7. Install new heating element with new rubber 0 rings (2)
mounted on terminal ends, and spreaders loosely mounted
in the center of the stacked elements.
8. Replace the heating elements, terminal end first at
approximately
45" angle, slipping the terminal ends
through the front wall of the frypot.
9. Replace the brass nut and washer on the heating element
terminals. Tighten the brass nuts to 30 foot lbs. of torque.
10. Move the element spreaders from the center of the
element, and tighten.
11. Replace the thermostat and high limit bulb holder and
tighten screw which holds the bulb in place.
econnect the wires to the appropriate terminal as labeled
when they were removed.
13. Replace the front control panel.