Henny Penny 520 Service Manual page 15

Compact pressure fryer
Hide thumbs Also See for 520:
Table of Contents

Advertisement

el
520
ke
15
High Temperature
Control
Lid/Locking
Assembly
Condensate Drain Pan
Fun~tio~
The high temperature thermostat is a manual reset control
which senses the temperature of the shortening. If the shorten-
ing temperature exceeds the safe operating limit, this control
will remove power from the contactors, thus removing heat
to the cook pot. When the temperature of the shortening drops
to preset safe operating limit, the control must be manually
reset. The reset button is located on the upper surface of the
recess in the front panel below the regulating thermostat.
Before pressure will build in the cook pot, the lid must be closed
and locked. To close the lid, push the lid down with one hand
by using the plastic handle on top of the lid. While holding the
lid closed with one hand,. turn the handle on the latch
counterclockwise 160 o (until it contacts the stop) to lock the lid.
DO NOT place your free hand on top of the lid during
the latching procedure. The surface may be hot and
burns could result.
The lid will not latch or pressure build unless the handle is fully
latched. As pressure builds within the cook pot, the handle will
be locked in place. As long as the locking assembly is engaged,
it will prevent the handle from being moved clockwise and
opening the lid. The locking assembly disengages when the
internal pressure falls below 1 PSI (6.8 KPa).
The condensate drain pan is located behind the panel, below
the drain and filter valve handles. Remove the panel and the
condensate pan is located on the left. It can be easily removed
by grasping the handle and pulling out carefully. The conden-
sation pan should be emptied daily.