correction
CTIQN (Continued)
Defective motor.
Motor thermal protector
Check/replace motor.
* Reset thermal switch.
Motor hums but will
not pump
* Clogged lines or pump.
* Remove and clean pump lines.
* Replace pump seal, rotor and
rollers.
Shortening will not
heat
eating of shortening
too slow
Shortening
overheating
TENING SEC
Blown fuse or tripped breaker
at supply box or control panel.
Blown fuse at control panel.
Faulty main switch.
Check cord and plug. Check
power at receptacle.
Faulty contactor.
Faulty thermostat.
Faulty high limit control
switch.
Low or improper voltage.
Weak or burnt out elements.
Points in contactor bad.
Wires loose.
Burnt or charred wire
connection.
Check thermostat
Check contactor for not
opening.
* Reset breaker or replace fuse.
* Check fuse.
* Check main switch.
Check cord and plug and power
at wall receptacle.
* Check contactor.
* Check thermostat'.
Check high limit control switch.
Use a meter and check the
receptacle against data plate.
Check heating elements.
Check contactor.
* Tighten.
Replace wire and clean
contactors.
* Calibrate thermostat
* Check faulty thermostat
Check faulty contactor.