Henny Penny 520 Service Manual page 34

Compact pressure fryer
Hide thumbs Also See for 520:
Table of Contents

Advertisement

ING SECTIQN
Foaming or boiling
over of shortening
Shortening will not
drain from fry-pot.
Timer fails to run
Buzzer continues to
buzz
Buzzer will not buzz
Timer will not reset
Timer light out
Water in shortening.
Condensation line stopped up.
Improper or bad shortening.
Improper filtering.
* Improper rinsing after
cleaning the fryer.
Drain valve clogged with
crumbs.
Drain valve will not open by
turning handle.
* At the end of frying cycle,
drain shortening and clean
frypot. Add fresh shortening
and check procedure for raising
lid.
* Remove and clean condensation
line.
Use recommended shortening.
* Refer to the procedure
covering filtering the
shortening.
Clean and neutralize the frypot.
Rinse with vinegar to remove
the alkaline then rinse with hot
water and dry frypot.
* Open valve - force cleaning
brush through drain opening.
Replace cotter pins in valve
coupling.
No power input
Timer set at zero.
Faulty microswitch.
Possible faulty buzzer.
Timer indicator not returning
to zero.
Faulty timer.
Faulty lamp.
Check timer switch
Check timer motor
Set timer indicator to a setting
other than zero.
Check and replace faulty
microswitch.
Check buzzer, replace if. faulty.
* Replace timer.
* Replace timer.
Replace lamp.