Danfoss ERC 102 Reference Manual page 49

Refrigeration controller
Table of Contents

Advertisement

Assignments
Button 2 Config
Button 3 Config
Button 4 Config
Pass-word level1
Pass-word level2
Pass-word level3
Cabinet Light Control
Source
Light off delay
ERC menu
Description
code
ASi
Assignment of inputs and outputs
b2C
Upper left button configuration .
tP:Increase Setpoint
tn: Decrease setpoint
ECo: Toggle Eco mode
Lig: Toggle light
dEF: Toggle defrost
SuP: Activate Super-Cool /Pull-down
diP : Increase display intensity
din : Decrease display intensity
noP: Not operating
b3C
Upper right button configuration .
tP:Increase Setpoint
tn: Decrease setpoint
ECo: Toggle Eco mode
Lig: Toggle light
dEF: Toggle defrost
SuP: Activate Super-Cool /Pull-down
diP : Increase display intensity
din : Decrease display intensity
noP: Not operating
b4C
Lower right button configuration .
tP:Increase Setpoint
tn: Decrease setpoint
ECo: Toggle Eco mode
Lig: Toggle light
dEF: Toggle defrost
SuP: Activate Super-Cool /Pull-down
diP : Increase display intensity
din : Decrease display intensity
noP: Not operating
PS1
Level 1 Password (End user, shop owner), 0= disabled
PS2
Level 2 Password (Technical field service), 0= disabled
PS3
Level 3 Password (OEM), 0= disabled; choose a secure number, e .g . 735
CLC
Cabinet light management
Lig: button only"
Ldo: door (and button if defined) only
LEC: Economy (and button if defined) only
Lod
Light off delay [sec] after door has been closed
ERC 102 Reference manual – APPENDIX I: PARAMETER QUICK LIST
49