Pull Down
Pull-down Initiate
Temperature
Pull-down Cycling
Pull-down defrost Interval
Pull-down duration
Pull-down limit temp
Pull-down reduction
temp Δt
Auto-Heater Control
Automatic heater mode
enable
Energy mode delay
Heater displacement
temperature
Condenser Protection
Condenser Alarm Limit
Condenser Block Limit
Condenser OK limit
Condenser Low Temp .
Limit
Display
Display Unit
Display Resolution
Display Range Limit
Display Delay
Display Offset
Lock-time After defrost
Show Economy state
Show Pull Down state
Show Defrost
Display Intensity
ERC menu
Description
code
Pud
Pull down settings
Pit
If the cabinet temperature is above this temperature for >1h, pull-down mode is activated
PCy
Minimum duration [min] of the pull-down mode, starting at PiT
Pdi
Defrost interval during pull-down . Over-rules the defrost interval in normal mode .
Pdd
Maximum duration [min] of the pull-down mode, starting at PiT
PLt
A safety feature; the lowest temperature allowed during pull-down .
Prt
A calculation value for pull-down performance improvement . Instructions: See manual
ERC menu
Description
code
AHC
Auto-Heater settings (only if heater fitted for outdoor use in cold climates)
AuH
yES: Activate heater if ambient temperature is below desired cabinet temperature
End
Delay in minutes between heater and compressor operation
Hdi
Heater displacement or OFFSET temperature relative to desired temperature .
ERC menu
Description
code
Con
Condenser protection settings
CAL
If condenser sensor exceeds this temperature, alarm is activated
CbL
If this temperature is exceeded, compressor will be stopped .
CoL
Temperature at which compressor may start after a stop due to exceeding CbL
CLL
Temperature below which the compressor is not allowed to start
ERC menu
Description
code
diS
Display settings
CFu
F: Fahrenheit; C: Celsius
rES
Display resolution for temp: 0 .1, 0 .5 or 1 .0 C/F
rlt
Limits displayed temperature to actual setpoint +/- differential; may be illegal in some countries
ddL
Time period for moving average temperature display
doF
Display a different temperature relative to measured temperature
dLt
Display lock time after defrost [0-60 min]
SEC
yES: display will show "Eco" when in Eco mode . nO: temperature will be shown
SSC
yES: "SC " will be displayed during Pull down; nO: "SC " will not be displayed .
SdF
yES: display will show deF during defrost ; no: Display will show temp
din
Display intensity when no ambient sensor; min intensity with sensor