ERC 102 Reference manual – APPENDIX I: PARAMETER QUICK LIST
ERC menu
Description
code
ASi
Assignment of inputs and outputs
S1C
Sensor type input 1 :Stn: Standard NTC 5k @25°C (EKS211); Ldr: Light sensor; dig: binary input
S2C
Sensor type input 2 :Stn: Standard NTC 5k @25°C (EKS211); Ldr: Light sensor; dig: binary input
S3C
Sensor type input 3 :Stn: Standard NTC 5k @25°C (EKS211); Ldr: Light sensor; dig: binary input
S1A
Application to be controlled with Sensor D .
nC: Not connected
SCo: Temperature control
EuA: Evaporator temperture
Con: Condenser temperature (Condenser cleaning)
LS1: Light sensor(Ldr), Luminens, delicated for Economy detection
LS2: Light sensor(Ldr), Luminens, delicated for LED intensity scope
LS3: Light sensor(Ldr), Luminens, delicated for both Economy detection and LED intensity scope
doC: Door contact, Contact closed when door closed
doo: Door contact, Contact open when door closed
S2A
Application to be controlled with Sensor C .
nC: Not connected
SCo: Temperature control
EuA: Evaporator temperture
Con: Condenser temperature (Condenser cleaning)
LS1: Light sensor(LDR), Luminens, delicated for Economy detection
LS2: Light sensor(LDR), Luminens, delicated for LED intensity scope
LS3: Light sensor(LDR), Luminens, delicated for both Economy detection and LED intensity scope
doC: Door contact, Contact closed when door closed
doo: Door contact, Contact open when door closed
S3A
Application to be controled with Sensor B .
nC: Not connected
SCo: Temperature control
EuA: Evaporator temperture
Con: Condenser temperature (Condenser cleaning)
LS1: Light sensor(LDR), Luminens, delicated for Economy detection
LS2: Light
diC
Sensor A (digital)
doC: Door contact, Contact closed when door closed
doo: Door contact, Contact open when door closed
dio: One wire digital communication
buS: MODBUS communication
o1C
CoP: Compressor; PiL: Pilot Relay (No zero-cross); HEt: Inverse output, Heating application
o2C
no:Not used; dEF: Elec defr heater/hot gas valve;ALA:Alarm output;FAn:Fan control;Lig:Light control
o3C
nO: Not used; ALA: Alarm output; FAn: Fan control; Lig: Light control
o4C
nO: Not used; ALA: Alarm output; Lig: Light control
b1C
Lower left button configuration .
tP:Increase Setpoint
tn: Decrease setpoint
ECo: Toggle Eco mode
Lig: Toggle light
dEF: Toggle defrost
SuP: Activate Super-Cool /Pull-down
diP : Increase display intensity
din : Decrease display intensity
noP: Not operating