9.
To remove the encoder, lift the lock-
ing tab, and turn the encoder to the left
(counterclockwise) as far as it will go. Lift
the encoder straight up so that the shaft
slides out of the rubber console seal, and
remove it from the console. NOTE: Do not
flex the encoder ribbon cable wires at the
UI board or they could break.
Remove
Lift Locking Tab
10. To remove the user interface board:
a) Remove the encoder (see step 9).
b) Using a flat-blade screwdriver, care-
fully pry the front edge of the user in-
terface board up, then pull the board
forward, and remove it from the con-
sole (see the top right photo).
Encoder Wires
Encoder
Locking Tab
Pull Shaft From Seal
User Interface Board
Pry Up Edge Of Board
REASSEMBLY NOTE: When you reinstall
the encoder on the UI board, make sure that
the rubber seal does not become dislodged
when installing the encoder shaft.
Rear Of Console
11. To remove the machine control:
a) Disconnect the machine control board
connectors at P8, P9, P13, and P14,
then pull the red and black wires off the
heater relay terminals. NOTE: On dual
element models, also disconnect the
violet and black wires from the second
heater relay terminals.
b) Remove the hex-head screw from the
rear of the machine control housing.
P14
P13
Continued on the next page.
4-3
Console Seal
Machine Control
Housing Screw
Heater Relay
P9
P8
RD
BK

Hide quick links: