Burner Ignitor; Electric Heater (Dual Element) - Maytag Bravos MED6300TQ Technical Education

Electric & gas dryers
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

BURNER IGNITOR

Burner Ignitor
Refer to page 4-15 for the procedure for ac-
cessing the gas burner assembly.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Disconnect the ignitor wire connector
from the main harness connector.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
2-wire connector pins. The meter should
indicate between 50 and 500 Ω.
WARNING
Electrical Shock Hazard
2-Wire Connector
5-4
ELECTRIC HEATER
(DUAL ELEMENT)
Dual Element
Heater
Refer to page 4-13 for the procedure for ac-
cessing the electric heater.
1.
Unplug dryer or disconnect power.
2.
Disconnect the wires from the heater ter-
minal block.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the indi-
cated heater terminals. The meter should
indicate as follows:
COM & terminal 1 = 15 - 25 Ω
COM & terminal 2 = 15 - 25 Ω
Terminals 1 & 2 = 30 - 50 Ω
COM
1
2

Hide quick links: