Maintenance; Replacing Carbon Brushes - Erbauer ERB2502SE User Manual

254mm (10”) compound mitre saw
Table of Contents

Advertisement

MAINTENANCE

Note: This maintenance section is the
best section for all the saws and should
be used as a master for all the mitre saws
when the following changes have been
completed.
Danger: To avoid injury, never
put lubricants on the blade while it is
spinning.
Warning: To avoid fire or toxic
reaction, never use petrol, naphtha
acetone, lacquer thinner or similar highly
volatile solvents to clean the mitre saw.
Warning: For your safety, this saw
is double-insulated. To avoid electrical
shock, fire or injury, use only parts
identical to those identified in the parts
list. Reassemble exactly as the original
assembly to avoid electrical shock.

1. Replacing carbon brushes

Replace both carbon brushes when either
has less than 6 mm length of carbon
remaining, or if the spring or wire is
damaged or burned. To inspect or replace
brushes, first unplug the saw. Then remove
the black plastic cap (1) on the side of the
motor (2). Remove the cap cautiously,
because it is springloaded. Then pull
out the brush and replace. Replace for
the other side. To reassemble reverse
the procedure. The ears on the metal
end of the assembly go in the same hole
the carbon part fits into. Tighten the cap
snugly, but do not overtighten. (See fig.36)
31
254MM (10") COMPOUND MITRE SAW
254MM (10") COMPOUND MITRE SAW
Fig 36
Note: To reinstall the same brushes, first
make sure the brushes go back in the way
they came out. This will avoid a break-
in period that reduces motor performance
and increases wear.
Replacement Parts available from 01709
876611.