Important !
Connect only normally
closed (N/C) reed switches
to HWIN1 and/or HWIN2.
Other types of hardwire
detectors should not be
used.
Note
Do not install the resistor at
the panel terminals. This
does not provide supervision
of the wire.
Simon Security System
Hardwire Exterior Siren without Supervision
With Option 53 turned off, connect the Hardwire Exterior Siren (13-046) to the panel
without a resistor as shown in Figure 6
A C
A C
H W I N 2
Black
Figure 6. Hardwire Exterior Siren without Supervision
Wiring Hardwire Contacts
You can connect hardwire reed switches (normally closed loop only) to HWIN1 and/or
HWIN2, if either terminal is not being utilized for a hardwire siren.
The total resistance of the wire loop must not exceed 3 ohms. This allows you to use
up to 200 feet of 2-conductor, 22-gauge stranded wire.
Connect hardwire reed switches to the panel using a 47k resistor as shown in Figure 7.
The resistor must be connected at the last switch in the circuit.
A C
A C
D C O U T
H W I N 2
47k
Resistor
Figure 7. Connecting Normally Closed Hardwire Reed Switches
Wiring a Phone Line to the Panel
You can connect a phone line to the panel for systems monitored by a central monitor-
ing station and/or systems that notify users by a digital pager or voice event notifica-
tion.
Basically, there are two methods for connecting the panel to a phone line; full line sei-
zure and no line seizure.
D C O U T
H W I N 1
Red
H W I N 1
12