Note
The RF Electronic Thermo-
stat is automatically tested
when a sensor test begins.
The panel will announce,
Sensor XXX activated, sta-
tus is one, if the thermostat
is OK.
Note
If a sensor does not meet
the minimum transmission
beep requirements, refer to
the "If a Sensor Fails the
Sensor Test" section of this
manual
43
The panel will prompt you to trip each sensor one at a time. You may follow the panel voice
prompting or test the sensors in any order. Use the "Sensor Tripping Instructions" table on
the next page to trip sensors.
Sensor
Door/Window
Freeze
Water
Carbon Monoxide Alarm
Glass Guard
Motion Sensor
Rate-of-Rise Heat Detector
Shock
Smoke
Panic Buttons
KeyChain Touchpad
Remote Handheld Touchpad
2-Way RF Touchpad
6.
Interior sirens and speakers sound transmission beeps and a voice announcement
identifies the tripped sensor. Each beep represents one RF packet. Count the num-
ber of beeps and refer to the "Minimum Beeps" table for minimum requirements.
After the beeps, the panel announces, Sensor Name is activated, sensor status is XX
(XX = number of RF packets). The system will continue to prompt for sensors that
have not yet been tested. When all sensors have been tested the panel will
announce, Sensor test complete, press DONE.
Type of Sensor
Wireless Intrusion Sensors
Wireless Smoke & Heat Sensors
Wireless Environmental/Panic Buttons
Hardwire Loops, RF Thermostat
Emergency Buttons (Remote Handheld Touchpads only)
Sensor Tripping Instructions
Open the secured door or window.
Apply ice in a plastic bag to the sensor. Do not
allow the sensor to get wet.
Press a wet rag or wet finger over both of the
round, gold-plated terminals on the underside of
the sensor.
Unplug the CO Alarm. Plug it back in, wait 5 sec-
onds, then press the TEST/RESET button until the
unit beeps 8 times.
Tap the glass 3 or 4 inches from the sensor.
Avoid the Motion Sensor field of view for 5 minutes,
then enter its view.
Rub your hands together until warm, then place
one hand on the detector for 30 seconds.
Tap the glass twice, away from the sensor. Wait at
least 30 seconds before testing again.
Press and hold the test button until the system
sounds transmission beeps.
Press and hold the appropriate panic button(s) for
3 seconds.
Press and hold LOCK and UNLOCK simulta-
neously for 3 seconds.
Press and hold the 2 EMERGENCY buttons simul-
taneously for 3 seconds.
Press and hold the 2 EMERGENCY buttons simul-
taneously for 3 seconds.
Minimum Beeps
Do This
Number of Beeps
7–8
7–8
7–8
1
7-8